Abstract
The spatial modification of the glazed façade is a part of the overall façade’s creation scheme. Despite the important aesthetical function, serrated and finned facades are also seen as an important tool of daylight management in buildings, especially when façade is partially glazed and partially opaque. This allows guiding scattered daylight deep into the room, simultaneously reducing the impact of direct solar radiation. The presented paper analyses the impact of different geometries of half-glazed (with shading elements) finned and serrated facades on the user’s visual comfort (daylight factor and summer solar exposure). The analyzed façades are of different geometry and south-facing located in 50° latitude in Wroclaw. The calculations were done using the De Luminæ software (DL-Light platform) with SketchUp. The analysis allowed to identify – for different typologies of serrated façade – the risks of glare and overheating and the potential need for sunlight protection. The software also helps to the position shading surfaces to control the potential glare.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Karlsen, L., et al.: Solar shading control strategy for office buildings in cold climate. Energy Build. 118, 316–328 (2016)
Brzezicki, M.: The influence of reflected solar glare caused by the glass cladding of a building: application of caustic curve analysis. Comput. Aided Civ. Infrastruct. Eng. 27(5), 347–357 (2012)
John, N.: Climate based façade design for business buildings with examples from central London. Buildings 5, 16–38 (2015)
Fernandes, L.L., et al.: Angular selective window systems: assessment of technical potential for energy savings. Energy Build. 90, 188–206 (2015)
Konstantzos, I., Tzempelikos, A.: Daylight glare evaluation with the sun in the field of view through window shades. Build. Environ. 113, 65–77 (2017)
Roberts, G.C.K.: Encyclopedia of Biophysics. Springer, Berlin (2013)
Perry, M.J.: Mechanisms of discomfort glare. Lighting Res. Technol. 22(3), 159 (1990)
Suk, J.Y., Schiler, M., Kensek, K.: Absolute glare factor and relative glare factor based metric: predicting and quantifying levels of daylight glare in office space. Energy Build. 130, 8–19 (2016)
Acknowledgments
This research was supported in part by a grant from the Polish Ministry of Science and Higher Education (S80401-0067-10-K0106 granted through the mechanism of dotation by Wroclaw University of Science and Technology). The author thanks the manufacturers of the De Luminæ software (DL-Light platform) for the test version, that was made available for the research.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Brzezicki, M. (2020). Serrated and Finned Glazed Facades’ Impact on the User’s Visual Comfort. In: Charytonowicz, J., Falcão, C. (eds) Advances in Human Factors in Architecture, Sustainable Urban Planning and Infrastructure. AHFE 2019. Advances in Intelligent Systems and Computing, vol 966. Springer, Cham. https://doi.org/10.1007/978-3-030-20151-7_17
Download citation
DOI: https://doi.org/10.1007/978-3-030-20151-7_17
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-20150-0
Online ISBN: 978-3-030-20151-7
eBook Packages: EngineeringEngineering (R0)