Abstract
The first step in processing of physiological signals is usually the improvement of the signal-to-noise ratio. However, the applicable filtering methods not only suppress noise but also distort the signal. As a result, parameters derived from filtered physiological signals are also distorted. The paper evaluates filtering methods applied to electrocardiographic (ECG) and photoplethysmographic (PPG) signals in the process of calculating heart period (HP) and pulse wave transit time (PWTT). Band-pass filtering applied in the course of QRS detection causes a shift in R-peak location depending on the QRS waveform. Following QRS detection accurate R-peak localization is suggested using re-filtering of the original signal. The HP was calculated as the time interval between two adjacent R-peaks and also as the time interval between two adjacent local minima in PPG (PPGmin). Both real and simulated data were used for the evaluation. In the latter case the fiducial points of the signals (ECG R-peak and PPGmin locations) were exactly known providing reference positions for the evaluation of filter distortion. Inappropriate filtering shifts the fiducial points. This causes a significant error while calculating parameters by subtraction, like RR interval of heart cycles (tRR, difference of two consecutive R-peak locations) or PWTT (difference of PPGmin and the associated R-peak location). Even more accurate R-peak and PPGmin localization is needed when variation in tRR and PWTT is analyzed. These variations characterize the actual stress level of a person before or during blood pressure measurement more accurately than average heart rate displayed by commercially available blood pressure monitors. Based on accurate R-peak and PPGmin localization it has been confirmed that for the same heart cycle the time interval is different between two R-peaks and two PPGmins.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Sörnmo, L., Laguna, P.: Electrocardiogram (ECG) Signal Processing. Wiley Encyclopedia of Biomedical Engineering. Wiley, Hoboken (2006)
Floran, J.S.: Blood pressure variability: a novel and important risk factor. Can. J. Cardiol. 29(5), 557–563 (2013)
Bernston, G.G., Bigger Jr., J.T., Eckberg, D.L., Grossman, P., Kaufmann, P.G., et al.: Committee report: heart rate variability: origins, methods and interpretive caveats. Psychophysiol. J. 34(6), 623–648 (1997)
Jobbágy, Á., Csordás, P., Mersich, A.: Blood pressure measurement at home. In: Proceedings of World Congress on Medical Physics and Biomedical Engineering 2006, pp. 3453–3456. Springer, Heidelberg (2007)
Csordás, P., Mersich, A., Jobbágy, Á.: Advanced indirect method for measuring blood pressure. Period. Polytech. Electr. Eng. 53(3–4), 115–121 (2011)
Friesen, G.M., Jannett, T.C., Jadallah, M.A., Yates, S.L., Quint, S.R., Nagle, H.T.: A comparison of the noise sensitivity of nine QRS detection algorithms. IEEE Trans. Biomed. Eng. 37(1), 85–98 (1990)
Thakor, N.V., Webster, J.G., Tompkins, W.J.: Estimation of QRS complex power spectra for design of a QRS filter. IEEE Trans. Biomed. Eng. 11, 702–706 (1984)
Kohler, B.-U., Hennig, C., Orglmeister, R.: The principles of software QRS detection. IEEE Eng. Med. Biol. Mag. 21(1), 42–57 (2002)
Pan, J., Tompkins, W.J.: A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. 32(3), 230–236 (1985)
Elgendi, M., Jonkman, M., DeBoer, F.: Heart rate variability and the acceleration plethysmogram signals measured at rest. In: International Joint Conference on Biomedical Engineering Systems and Technologies, pp. 266–277. Springer, Heidelberg (2010)
Acknowledgement
The research has been supported by the European Union, co-financed by the European Social Fund (EFOP-3.6.2-16-2017-00013).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
The authors declare that they have no conflict of interest.
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Nagy, P., Jobbágy, Á. (2020). Accurate Calculation of Heart Period and Pulse Wave Transit Time. In: Henriques, J., Neves, N., de Carvalho, P. (eds) XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019. MEDICON 2019. IFMBE Proceedings, vol 76. Springer, Cham. https://doi.org/10.1007/978-3-030-31635-8_32
Download citation
DOI: https://doi.org/10.1007/978-3-030-31635-8_32
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-31634-1
Online ISBN: 978-3-030-31635-8
eBook Packages: EngineeringEngineering (R0)