Abstract
Computed tomography (CT) is an imaging modality producing 3D images from sets of 2D X-ray images taken around the object. The images are noisy by nature, and segmentation of the 3D images is tedious. Also, detection of low contrast objects may be difficult, if not impossible. Here, we propose an independent component analysis (ICA) based method to process sets of 2D projection images prior to 3D reconstruction to remove noise, and to enhance objects for detection and segmentation. In this paper, a proof-of-concept is provided: the proposed method was able to separate noise and image components, as well as to make visible objects that were not observable in 3D images without processing. We demonstrate our method in object separation with 2D slice image processing simulations, and by enhancing a 3D image of a polymer sample taken with Xradia MicroXCT-400. The method is applicable in any CT tomography for which a number of project image sets with different contrasts can be taken, e.g., in multispectral fashion.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Cierniak, R.: X-ray Computed Tomography in Biomedical Engineering. Springer, London (2011). https://doi.org/10.1007/978-0-85729-027-4
Hyvärinen, A., Karhunen, J., Oja, E.: Independent Component Analysis. Wiley, Hoboken (2001). https://doi.org/10.1002/0471221317
Hyvärinen, A.: Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans. Neural Netw. 10(3), 626–634 (1999). https://doi.org/10.1109/72.761722
Hyvärinen, A., Oja, E.: Independent component analysis: algorithms and applications. Neural Netw. 13(4–5), 411–430 (2000). https://doi.org/10.1016/S0893-6080(00)00026-5
Tang, S., Wang, Y., Chen, Y.-W.: Application of ICA to X-ray coronary digital subtraction angiography. Neurocomputing 79, 168–172 (2012). https://doi.org/10.1016/j.neucom.2011.10.012
Chen, Y.W., Han, X., Oikawa, S., Fujita, A.: Independent component analysis for removing X-ray scatter in X-ray images. In: Proceedings of the 2007 IEEE Instrumentation and Measurement Technology Conference, pp. 1–4. IEEE, Piscataway (2007). https://doi.org/10.1109/IMTC.2007.379278
FastICA package for Matlab. http://www.cis.hut.fi/projects/ica/fastica/. Accessed 18 Apr 2019
Jolliffe, I.T.: Principal Component Analysis. Springer, Heidelberg (2002). https://doi.org/10.1007/b98835
Tanskanen, J.M.A., Viik, J.J.: Independent component analysis in ECG signal processing. In: Millis, R.M. (ed.) Advances in Electrocardiograms, pp. 349–372. InTech, Rijeka (2012). https://doi.org/10.5772/22719
Acknowledgments
The work of J. M. A. Tanskanen has been supported by Jane and Aatos Erkko Foundation, Finland, under the project Biological Neuronal Communications and Computing with ICT. The work of M. Hannula has been supported by the Human Spare Parts Project funded by Finnish Funding Agency for Technology and Innovation (TEKES).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Ethics declarations
No conflict of interest.
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Hannula, M., Hyttinen, J.A.K., Tanskanen, J.M.A. (2020). Enhancing CT 3D Images by Independent Component Analysis of Projection Images. In: Henriques, J., Neves, N., de Carvalho, P. (eds) XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019. MEDICON 2019. IFMBE Proceedings, vol 76. Springer, Cham. https://doi.org/10.1007/978-3-030-31635-8_46
Download citation
DOI: https://doi.org/10.1007/978-3-030-31635-8_46
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-31634-1
Online ISBN: 978-3-030-31635-8
eBook Packages: EngineeringEngineering (R0)