Abstract

The BioBall device, developed for wrist function rehabilitation, allows the execution of movements with a greater level of control. A component was added to make it possible to read the range of motion of the patient’s wrist. Thus, this project came up intending to evaluate the performance and suitability of the BioBall device for wrist function rehabilitation. To this end, a technical evaluation was performed in order to verify the consistency and accuracy of BioBall. Technical tests consisted of amplitude readings taken by the device, either in automatic or manual mode, “Passive Exercise” and “Physical Exercise” respectively. From the results obtained in this analysis it was concluded that the BioBall device, besides functioning correctly, can collect the angular data with consistency and it is suitable to follow the evolution of a patient's rehabilitation. In order to evaluate whether the BioBall device performs reproducible and repeatable range of motion measurements, a test-retest was performed on healthy subjects (with the space of one week). The maximum amplitude of each wrist movement of the participants was measured. The results of the statistical analysis showed that, although there is some variation in the amplitudes obtained between the test and the retest, the device has good reliability in measuring the range of motion of the wrist.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Pina, J.A.E.: Anatomia Humana da Locomoção. 5th edn. Lidel- Edições Técnicas, Lda., Lisboa (2014)

    Google Scholar 

  2. Akdoğan, E., Aktana, M.E., Korua, A.T., Arslana, M.S., Atlıhana, M., Kuran, B.: Hybrid impedance control of a robot manipulator for wrist and forearm rehabilitation: performance analysis and clinical results. Mechatronics 49, 77–91 (2018)

    Article  Google Scholar 

  3. Llopis, E., Restrepo, R., Kassarjian, A., Cerezal, L.: Overuse injuries of the wrist. Radiol. Clin. North Am. 57(5), 957–976 (2019)

    Article  Google Scholar 

  4. Cooney, W.P.: The Wrist: Diagnosis and Operative Treatment, 2nd edn. Lippincott Williams & Wilkins (2010)

    Google Scholar 

  5. Hagert, E.: Proprioception of the wrist joint: a review of current concepts and possible implications on the rehabilitation of the wrist. J. hand 23(1), 2–17 (2010)

    Google Scholar 

  6. Bruder, A.M., Taylor, N.F., Dodd, K.J., Shields, N.: Physiotherapy intervention practice patterns used in rehabilitation after distal radial fracture. Physiotherapy 99(3), 233–240 (2013)

    Article  Google Scholar 

  7. Karagiannopoulos, C., Michlovitz, S.: Rehabilitation strategies for wrist sensori-motor control impairment: from theory to practice. J. Hand Ther. 22(2), 154–165 (2016)

    Article  Google Scholar 

  8. Logicbus: Encoders. https://www.logicbus.com.mx/info_encoders.php. Accessed 23 Aug 2019

  9. Cuppone, A.V., Squeri, V., Semprini, M., Masia, L., Konczak, J.: Robot-assisted proprioceptive training with added vibro-tactile feedback enhances somatosensory and motor performance. PLoS ONE 11(10), e0164511 (2016)

    Google Scholar 

  10. Frank Rauch, M.D.: Vibration therapy. Dev. Med. Child Neurol. 51(4), 116–168 (2009)

    Google Scholar 

  11. Hogeweg, J., Langereis, M., Bernards, A., Faber, J., Helders, P.: Goniometry-variability in the clinical practice of a conventional goniometer in healthy subjects. Eur. J. Phys. Med. Rehabil. 4(1), 2–7 (1994)

    Google Scholar 

  12. Koo, T.K., Li, M.Y.: A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15(2), 155–163 (2016)

    Article  Google Scholar 

  13. Santos, C.M., Ferreira, G., Malacco, P.L., Sabino, G.S., Moraes, G.F.S., Felício, D.C.: Intra and inter examiner reliability and measurement error of goniometer and digital inclinometer use. Locomotor Apparatus Exerc. Sports 18(1), 38–41 (2012)

    Google Scholar 

Download references

Acknowledgements

This work has been supported by FCT – Fundação para a Ciência e Tecnologia within the R&D Units Project Scope: UIDP/04077/2020.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eurico Seabra .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2022 The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Silva, B. et al. (2022). Performance Evaluation of the BioBall Device for Wrist Rehabilitation in Adults and Young Adults. In: Machado, J., Soares, F., Trojanowska, J., Yildirim, S. (eds) Innovations in Mechatronics Engineering. icieng 2021. Lecture Notes in Mechanical Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-79168-1_13

Download citation

Publish with us

Policies and ethics