The purpose of a medical device alarm is to command the attention of the clinician for notification of an immediate or potential adverse patient condition. It should be actionable and requires a response. The frequency of false alarms has increased due to increased numbers of alarming devices, lack of standardization of alarms, and alarm settings with sensitivity over specificity. In some hospitals alarm signals can reach several hundred per patient, with most requiring no clinical intervention. Clinicians can become overwhelmed and desensitized by the frequency of these alarms. During the last six years, there have been patient deaths reported that were attributed to “alarm fatigue.” Clinical alarm hazards have been cited as being among the top ten health technology hazards for several years. As a result, a national initiative is underway in the United States focusing on safe use of alarms. Appropriate use of well-designed devices and an organized work environment can reduce risks and increase safety. Alarm customization, tailoring alarm parameters to individual patient needs, communication between clinicians, policies to empower clinicians and teamwork can help to create safer systems.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
AAMI, FDA, TJC, ACCE, and ECRI Institute Clinical Alarms Summit (2011). http://www.aami.org/publications/summits/2011_Alarms_Summit_publication.pdf
American Association of Critical-Care Nurses: Alarm management. http://ccn.aacnjournals.org/content/33/5/83.full. Accessed Feb 2017
Sawyer, D.: Do it by design: an introduction to human factors in medical devices. U.S. Department of Health and Human Services. https://elsmar.com/pdf_files/FDA_files/DOITPDF.PDF
FDA Guidance for Industry and Food and Drug Administration: Applying human factors and usability engineering to medical devices. https://www.fda.gov/downloads/MedicalDevices/…/UCM259760.pdf. Accessed Feb 2017
McClelland, G.H.: Use of signal detection theory as a tool for enhancing performance and evaluating tradecraft in intelligence analysis. https://www.nap.edu/read/13062/chapter/7#98. Accessed Feb 2017
Joint Commission Sentinel Event Alert. http://www.jointcommission.org/assets/1/18/SEA_50_alarms_4_5_13_FINAL1.PDF. Accessed Feb 2017
Cvach, M., Creighton, K.: Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms. http://ajcc.aacnjournals.org/content/19/1/28.abstract. Accessed Feb 2017
Sendelbach, S., Funk, M.: Alarm fatigue: a patient safety concern. AACN Adv. Crit. Care 24(4), 378–386 (2013). http://www.aacn.org/wd/cetests/media/acc3342.pdf
Joint Commission on Accreditation of Healthcare Organizations: The Joint Commission announces 2014 National Patient Safety Goal. Joint Comm. Perspect. 33(7), 1 (2013)
Guardia-LaBar, L.M., Scruth, E.: Alarm fatigue. Advance healthcare network. http://nursing.advanceweb.com/Continuing-Education/CE-Articles/Alarm-Fatigue.aspx. Accessed Feb 2017
Medical Equipment: Clinical Alarms Risk Assessment. http://www.courtemanche-assocs.com/wp-content/uploads/Clinical-Alarm-Risk-Assessment-Template. Accessed Feb 2017
Oster, C., Braaten, J.: High Reliability Organizations: A Healthcare Handbook for Patient Safety & Quality. Sigma Theta Tau International, Indianapolis (2016)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Sebastian, V., Brown, C.H. (2018). Alarm Management: A Systems Approach to Patient Safety. In: Freund, L., Cellary, W. (eds) Advances in The Human Side of Service Engineering. AHFE 2017. Advances in Intelligent Systems and Computing, vol 601. Springer, Cham. https://doi.org/10.1007/978-3-319-60486-2_6
Download citation
DOI: https://doi.org/10.1007/978-3-319-60486-2_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-60485-5
Online ISBN: 978-3-319-60486-2
eBook Packages: EngineeringEngineering (R0)